: Connect a voltmeter to the main board (Black to MP15 , Red to MP4/MP5 ). Adjust potentiometers P4 or P5 to reach exactly 0.500V (500mV) .
: Verify voltage at the sensor. Expected values are roughly 3.125V (0°) and 2.5V (45°) . 3. Pressure Transducer Maintenance
: Measure the signal between Pin 2 (signal) and Pin 1 (ground). Use a voltmeter at test point MP4 on the main board. 2. Angle Sensor Adjustment
: If replacing the system chip, ensure the notch faces the correct direction to avoid frying the board.
: Test that the system successfully disables crane functions during an overload condition.
Detailed wiring diagrams and flowcharts can be found in the PAT DS350 Service Manual or via WIKA Mobile Control Support . LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM